Case study · Outdoor equipment brand

A beacon housing that survives a 30-meter tumble

Redesign of an avalanche-safety transceiver housing for impact, cold-temperature performance and glove-friendly controls.

Client
Outdoor equipment brand
Industry
Outdoor & Sporting Goods
Duration
11 weeks
Team
4 people
Year
2024
1234ABCHOUSING ASSY, EXPLODEDDWG RO-1742REV CSCALE 1:1SHEET 1 / 1118.0LI-ION 2S · 3400 MAHEXPLODED VIEW12341 HOUSING, UPPER · PC/PBT GF152 SEAL, OVERMOLD · TPE 60A3 PCBA, MAIN · REV C4 HOUSING, LOWER · PC/PBT GF15
-32%
Field returns after launch
-30 °C
Validated operating temperature
4 days
Average turn per housing revision

01 · The challenge

The previous generation housing was cracking at the battery door in cold-weather drops, and returns were eroding margin and reputation in a category where trust is everything.

02 · What we did

  1. 01

    Reproduced the failure in our thermal chamber and drop rig within the first week, then instrumented it with high-speed video.

  2. 02

    Moved to a glass-filled PC/PBT blend with a redesigned latch geometry and a captive over-molded seal.

  3. 03

    Turned seven housing revisions in machined and SLS prototypes, each drop-tested cold-soaked at -30 °C.

  4. 04

    Ran a two-week field trial with patrollers at a Colorado ski area before tooling release.

03 · The outcome

The new housing passed 1.5 m cold drops on all faces and edges with zero cracks. Field returns for the housing dropped by roughly a third in the first season after launch.

“Revisions that took a month elsewhere took four days.”
Director of Product · Outdoor equipment brand

Next step

Have a program like this one?

Share as much or as little as you can. A senior engineer reads every inquiry and replies within one business day, usually with a few sharp questions and a suggested first step.